Ravenheat WH 100 User Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
COD 0017FOG13005/0 - 05/2012
THE WHITE BOILER COMPANY
a Ravenheat Group Company
Chartists Way, Morley, Leeds, LS27 9ET
Telephone : 0044(0)113 252 7007
Fax : 0044(0)113 238 0229
Website : www.ravenheat.co.uk e-mail : [email protected]
Ravenheat reserves the right to make changes and
improvements in our products which may affect the accuracy
of the information contained in this lea et.
4
Table of sequence codes
01: Interruption of gas supply or ame failure
04: Over operating temperature CH/DHW probe or system requires correctly setting on
boiler
06: Domestic Hot Water NTC sensor or NTC sensor wiring fault
12: Central Heating NTC sensor or NTC sensor wiring fault
17: Fan or fan wiring fault
28: Water pressure system too low (see sect. 1.4.1) or circulation fault
30: Flue overheat temperature
31: Flue NTC sensor or ue NTC sensor wiring fault
IMPORTANT:
If the reset has been attempted and the sequence code persists leave the appliance turn off and consult your
installer/service engineer immediately quoting the sequence code numbers.
BOILER FROST PROTECTION
The appliance has a built in frost protection device that protects the boiler from freezing. With the gas and
electric supplies ON and irrespective of any room thermostat setting, the frost protection device will
operate the pump when the temperature fallsbelow 10°C and will operate the burner when the temperature
falls below 5°C. The burner will switch off when the temperature reaches 27°C. When the frost protection
device operates “AF” is displayed on the digital display.
IMPORTANT NOTE:
The system should be protected by incorporating a system frost thermostat.